![]() ![]() Locate control system networks and remote devices behind firewalls, and isolate them from the business network.Minimize network exposure for all control system devices and/or systems, and ensure that they are not accessible from the Internet.ICS-CERT recommends that users take defensive measures to minimize the risk of exploitation of these vulnerabilities. The new package can be found at the following location on its web site: Unitronics has released an updated package, VisiLogic V9.8.09, to address these vulnerabilities. MITIGATION - Begin Update A Part 2 of 2. DIFFICULTYĪn attacker with a medium skill would be able to exploit these vulnerabilities. No known public exploits specifically target these vulnerabilities. These vulnerabilities could be exploited remotely. End Update A Part 1 of 2 - VULNERABILITY DETAILS EXPLOITABILITY A CVSS v3 base score of 9.8 has been assigned the CVSS vector string is (CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H).CVSS Calculator,, web site last accessed January 05, 2016. This web site will be active sometime after publication of this advisory. When parsing a specific file, the length of the filename is not validated, resulting in a heap-based buffer overflow.ĬVE-2015-7939NVD,, NIST uses this advisory to create the CVE web site report. VULNERABILITY CHARACTERIZATION VULNERABILITY OVERVIEWĬ ODE INJECTIONCWE-94: Improper Control of Generation of Code ('Code Injection'),, web site last accessed January 05, 2016. According to Unitronics, these products are used worldwide in multiple sectors. Unitronics VisiLogic OPLC IDE is an HMI and PLC application programming environment for Vision and SAMBA series controllers. Unitronics has offices in the United States and Israel and sells products through partners worldwide. ICS-CERT recommends that organizations evaluate the impact of these vulnerabilities based on their operational environment, architecture, and product implementation. Impact to individual organizations depends on many factors that are unique to each organization. Unitronics VisiLogic OPLC IDE Version 9.8.0.00 and previous.Ī successful exploit of these vulnerabilities could lead to remote code execution.Unitronics reports that the vulnerabilities affect the following products: ![]() Unitronics has produced an updated package to mitigate these vulnerabilities. HP’s Zero Day Initiative (ZDI) reported to ICS-CERT that Steven Seeley of Source Incite, Fritz Sands of ZDI, and Andrea Micalizzi discovered vulnerabilities in Unitronics VisiLogic OPLC IDE. This updated advisory is a follow-up to the original advisory titled ICSA-15-274-02 Unitronics VisiLogic OPLC IDE Vulnerabilities that was published November 12, 2015, on the NCCIC/ICS-CERT web site. ![]()
0 Comments
Leave a Reply. |